[1]何崇慧,全民强,边虎,等.钯-铂重整催化剂中铂含量测定的干扰因素及消除方法[J].石化技术与应用,2024,2:139-143.
HE Chong-hui,QUAN Min-qiang,BIAN Hu,et al.Interference factors and elimination method on the determination of Pt content in Pd-Pt reforming catalyst[J].Petrochemical technology & application,2024,2:139-143.
点击复制
钯-铂重整催化剂中铂含量测定的干扰因素及消除方法(PDF)
《石化技术与应用》[ISSN:1009-0046/CN:62-1138/TQ]
- 期数:
-
2024年2期
- 页码:
-
139-143
- 栏目:
-
- 出版日期:
-
2024-03-10
文章信息/Info
- Title:
-
Interference factors and elimination method on the determination of Pt content in Pd-Pt reforming catalyst
- 文章编号:
-
1009-0045(2024)02-0139-05
- 作者:
-
何崇慧; 全民强; 边虎; 牛承祥
-
中国石油石油化工研究院 兰州化工研究中心,甘肃 兰州 730060
- Author(s):
-
HE Chong-hui; QUAN Min-qiang; BIAN Hu; NIU Chen-xiang
-
Lanzhou Petrochemical Research Center,Petrochemical Research Institute,PetroChina,Lanzhou 730060,China
-
- 关键词:
-
钯-铂重整催化剂; 分光光度法; 铂含量; 干扰因素; 1; 2-环己二胺四乙酸; 氯化亚锡
- Keywords:
-
Pd-Pt reforming catalyst; spectrophotometry; Pt content; interference factor; 1; 2-cyclohexanediamine tetraacetic acid; Tin(Ⅱ) chloride
- 分类号:
-
TE 624.9+2;O 652
- DOI:
-
DOI:10.19909/j.cnki.ISSN1009-0045.2024.02.0139
- 文献标识码:
-
B
- 摘要:
-
按照NB/SH/ T 0570—2017检测标准,使用分光光度法测定了Al2O3基钯-铂重整催化剂中的铂含量,考察了络合物放置时间、氧化铝、共存元素钯等因素对铂含量测定的影响,并采取共存离子掩蔽法消除了钯的存在对铂含量测定产生的干扰。结果表明:氯铂酸锡络合物的最佳放置时间为1 h,基体氧化铝对铂元素的测定没有影响,钯的存在使得铂含量测定结果偏大;在每100 mL待测溶液中添加2.5 mL的1,2-环己二胺四乙酸(质量分数1.0%),可消除钯对铂含量测定的干扰;在优化条件下,测定HH-8及HH-9催化剂试样中铂质量分数平均值分别为0.237%,0.179%,相对标准偏差小于3%,方法检出限为0.16 mg/L,加标回收率为97.3%~101.0%。
- Abstract:
-
Pt content in Al2O3-based Pd-Pt reforming catalyst was determined by spectrophotometer method according to the detection standard of NB/SH/ T 0570—2017,the influence of the time of complex placement, alumina and coexisting element Pd on the determination of Pt was investigated, and the interference of Pd on the determination of Pt was eliminated by coexisting ion masking method. The results showed that the best placement time of the Tin chloroplatinate complex was 1 h, the Al2O3 had no effect on the determination of Pt, and by addition of 2.5 mL of 1,2-cyclohexanediamine tetraacetic acid (1.0% by mass fraction) per 100 mL of the solution to be determined and eliminated the interference of Pd to the determination of Pt. Under the optimum conditions, the average Pt mass fraction in HH-8 and HH-9 catalyst samples was 0.237% and 0.179%, respectively. The relative standard deviation was less than 3%. The detection limit was 0.16 mg/L, and the tagged recovery rates were 97.3%-101.0%.
参考文献/References
[1] 卢雯婷,陈敬超,冯晶,等. 贵金属催化剂的应用研究进展[J]. 稀有金属材料与工程,2012,41(1):184-187.[2] 李元美,白金,李剑,等. 铂、钯贵金属催化剂在加氢脱硫反应中的应用研究进展[J]. 精细石油化工,2018,35(2): 64-69.[3] 许韵华,赵海英,王永生,等. 含铂催化剂中铂含量的测定[J]. 北京交通大学学报,2004,28(6):58-60.[4] Stephen C,Algis N,James L. Analysis of spent noble metals bearing process catalysts[J]. Precious Metals,2007,28(3):66-70.[5] 朱利亚,陈云江,赵辉,等. 微波消解和精密电流滴定法测定铂类化合物中的铂含量[J]. 贵金属,2007,28(3):51-55.[6] 李中玺,周丽萍. 流动注射在线分离富集G电热原子吸收法测定地球化学样品中的痕量金、铂、钯[J].分析试验室,2003,22(3):8-12.[7] 翁漪. 负载型Pt/Al2O3催化剂中铂的测定[J].工业催化,2004,12(3):50-52.[8] 张天壤,张雪梅,于海斌. 用X射线荧光光谱法测定催化剂中铂钯含量[J].无机盐工业,2011,43(9):57-59.[9] 那铎,孙莹,马洪波. 电感耦合等离子体原子发射光谱(ICPGAES)法测定碳纳米管负载铂催化剂中铂的含量[J]. 中国无机分析化学,2017,7(4):93-96.[10] 侯君钊,张圣欢,闫爽,等. 钯含量分析方法研究进展[J]. 化学分析计量,2021,30(12):89-93.[11] 李晓凡,单红飞,刘博书. 电感耦合等离子体发射光谱法测定氧化铝基催化剂中铂元素[J].辽宁化工,2023,52(7):1075-1078.[12] 国家能源局. NB/SH/T 0570—2017 重整催化剂铂含量的测定 分光光度法[S].北京:中国石化出版社,2018.