|本期目录/Table of Contents|

[1]李淑杰,汲永钢,关旭,等.采用差示扫描量热法测定蜡滴熔点[J].石化技术与应用,2024,3:225-228.
 LI Shu-jie,JI Yong-gang,GUAN Xu,et al.Determination of drop melting point of wax by differential scanning calorimetry[J].Petrochemical technology & application,2024,3:225-228.
点击复制

采用差示扫描量热法测定蜡滴熔点(PDF)

《石化技术与应用》[ISSN:1009-0046/CN:62-1138/TQ]

期数:
2024年3期
页码:
225-228
栏目:
出版日期:
2024-05-10

文章信息/Info

Title:
Determination of drop melting point of wax by differential scanning calorimetry
文章编号:
1009-0045(2024)03-0225-04
作者:
李淑杰汲永钢关旭李奕睿
中国石油石油化工研究院 大庆化工研究中心,黑龙江 大庆 163714
Author(s):
LI Shu-jieJI Yong-gangGUAN XuLI Yi-rui
Daqing Petrochemical Research Center,Petrochemical Research Institute,PetroChina,Daqing 163714,China
关键词:
差示扫描量热滴熔点微晶蜡费托蜡聚乙烯蜡棕榈蜡
Keywords:
differential scanning calorimetrydrop melting pointmicrocrystalline waxfischer-tropsch waxpolyethylene waxcarnauba wax
分类号:
TE 626.8
DOI:
DOI:10.19909/j.cnki.ISSN1009-0045.2024.03.0225
文献标识码:
B
摘要:
采用差示扫描量热(DSC)法测定蜡滴熔点,研究了升(降)温速率、升温次数对测试结果的影响,并在最优条件下考察了DSC法测蜡滴熔点的重复性、准确性和再现性。结果表明:确定熔融曲线终止边的拐点温度为DSC法的滴熔点;DSC法测蜡滴熔点的最优条件为:第1次升(降)温速率均为20 ℃/min,第2次升温速率为5 ℃/min;该方法的重复性在0~0.2 ℃,再现性在0~1.1 ℃,均满足GB/T 8026—2014的要求。
Abstract:
The drop melting point of wax was determined by using differential scanning calorimetry (DSC), and the effects of heating(cooling) rate and heating times on the test results were studied. The repeatability, accuracy and reproducibility of DSC method for measuring wax drop melting point were investigated under the optimal conditions. The results showed that the inflection point temperature at the end of the melting curve was determined to be the drop melting point of the DSC method. The optimal conditions for measuring the drop melting point of wax by DSC method were as follows:the first heating(cooling) rate was 20 ℃/min, the second heating rate was 5 ℃/min. The repeatability of the method was 0-0.2 ℃, and the reproducibility was 0-1.1 ℃, which both met the requirements of GB/T 8026—2014.

参考文献/References

[1] 胡玉梅.微晶蜡市场分析及对行业发展的建议[J].化工技术经济,2004,22(3):4-7.[2] 王立荣,安良成.费托蜡市场分析与展望[J].合成材料老化与应用,2019,48(6):132-136.[3] 杨斌.聚乙烯蜡制备工艺进展[J].中外能源,2022,27(9):64-69. [4] 薛白,杨基和.石蜡改性-纯氧法合成巴西棕榈蜡替代品[J].江苏工业学院学报,2009,21(4):33-37. [5] International Standardization Organization Technical Committee.ISO 11357-3:2018 Plastics-differential scanning calorimetry (DSC)-part 3:Determination of temperature and enthalpy of melting and crystallization[S].Geneva:International Standardization Organization,2018:1-6.[6] American Society for Testing and Materials Committee.ASTM D 127-19 Standard test method for drop melting point of petroleum wax, including petrolatum[S].West Conshohocken:ASTM International,2019:1-10.[7] 全国石油产品和润滑剂标准化技术委员会石油蜡类产品分技术委员会.GB/T 8026—2014 石油蜡和石油脂滴熔点测定法[S].北京:中国标准出版社,2014:1-5.[8] 苏小琴,龙伟,刘秀兰,等.差示扫描量热仪的影响因素及测试技术优化[J].分析仪器,2019(4):74-79.[9] 全国能源基础与管理标准化技术委员会.GB/T 6425—2008 热分析术语[S].北京:中国标准出版社,2008:1-27.[10] 全国塑料标准化技术委员会通用方法和产品分会.GB/T 19466.3—2004 塑料 差示扫描量热法(DSC)第3部分:熔融和结晶温度及热焓的测定[S].北京:中国标准出版社,2004:1-8.[11] 全国化学标准化技术委员会.GB/T 28724—2012 固体有机化学品熔点的测定 差示扫描量热法[S].北京:中国标准出版社,2012:1-6.[12] 全国外科植入物和矫形器械标准化技术委员会.YY/T 0815—2010 差示扫描量热法测定超高分子量聚乙烯熔化焓、结晶度和熔点[S].北京:中国标准出版社,2011:1-8.[13] 刘江,余双平,傅利玉,等.DSC测定PP熔点过程中实验条件的优化[J].工程塑料应用,2014,42(1):88-92.[14] 黄钰香,庞承焕,林木良.DSC检测过程影响因素的探讨研究[J].广州化工,2008,36(5):1-6.[15] 刘力荣,陈敏剑,谢鹏.正交实验优化差示扫描量热仪(DSC)测定PBT熔点的实验条件[J].塑料工业,2017,45(5):99-101.

备注/Memo

备注/Memo:
-
更新日期/Last Update: 2024-05-10