|本期目录/Table of Contents|

[1]沈聪,姜磊,孙瑞光,等.燃气锅炉脱硝单元工艺优化[J].石化技术与应用,2023,5:377-381.
 SHEN Cong,JIANG Lei,SUN Rui-guang,et al.Process optimization of gas boiler denitration unit[J].Petrochemical technology & application,2023,5:377-381.
点击复制

燃气锅炉脱硝单元工艺优化(PDF)

《石化技术与应用》[ISSN:1009-0046/CN:62-1138/TQ]

期数:
2023年5期
页码:
377-381
栏目:
出版日期:
2023-09-10

文章信息/Info

Title:
Process optimization of gas boiler denitration unit
文章编号:
1009-0045(2023)05-0377-05
作者:
沈聪12姜磊3孙瑞光4王玉斌12张永华3陈卫军3
(1.中国石油石油化工研究院 兰州化工研究中心,甘肃 兰州 730060;2.石油石化污染物控制与处理国家重点实验室,甘肃 兰州 730060;3.中国石油宁夏石化公司 科技和规划发展部,宁夏 银川 753000;4.中国石油兰州石化公司 安全环保部,甘肃 兰州 730060)
Author(s):
SHEN Cong12JIANG Lei3SUN Rui-guang4WANG Yu-bin12ZHANG Yong-hua3CHEN Wei-jun3
(1. Lanzhou Petrochemical Research Center, Petrochemical Research Institute,PetroChina,Lanzhou 730060,China;2. State Key Laboratory of Petroleum Pollution Control,Lanzhou 730060,China;3. Ministry of Science, Technology, Planning and Development of Ningxia
关键词:
燃气锅炉脱硝浓度场催化剂氮氧化物稳定性
Keywords:
gas boilerdenitrationconcentration fieldcatalystnitrogen oxidestability
分类号:
X 742;TE 992.1
DOI:
DOI:10.19909/j.cnki.ISSN1009-0045.2023.05.0377
文献标识码:
B
摘要:
针对某化肥厂130 t/h燃气锅炉新增氨气选择性催化还原(NH3-SCR)脱硝单元投运后,烟气条件波动幅度大、喷氨量及出入口NOx质量浓度频繁波动等问题,结合工艺流程及离线检测数据分析了影响脱硝稳定性的因素,并优化了工艺。结果表明:通过优化调节前端低氮燃烧条件、喷氨条件,使脱硝段烟气组分更稳定且条件更加温和,催化剂床层温度提升20 ℃,入口NOx质量浓度降低110 mg/m3,出口NOx质量浓度降低至约15 mg/m3,保证了装置NOx达标(不大于100 mg/m3)排放,实现了装置连续稳定运行。
Abstract:
In view of the operation of the new selective catalytic reduction of ammonia (NH3-SCR) denitrification catalyst in the 130 t/h gas boiler in a fertilizer plant, the large fluctuation of flue gas conditions led to the frequent fluctuation of ammonia injection and NOx concentration at the entrance and exit of the denitrification unit. The factors affecting the stability of the subsequent denitrification were analyzed in combination with the process and offline detection data. The process was optimized. The results showed that by optimizing and adjusting the low nitrogen combustion conditions and ammonia injection conditions at the front end, the flue gas component of the denitration section was more stable and milder; the temperature of the catalyst bed was increased by 20 ℃; the inlet NOx mass concentration was reduced by 110 mg/m3, and the outlet NOx mass concentration was reduced to about 15 mg/m3. It ensured the NOx emission standard (≤100 mg/m3)of the unit and achieved continuous and stable operation of the unit.

参考文献/References

[1] 张志钢,潘瑛.天然气锅炉烟气余热回收与效率[J].山西财经大学学报,2013,35(Z 1):187.[2] 杜凯敏,秦刚华,祁志福,等.NH3-SCR脱硝催化剂的中毒及其抗毒策略[J].现代化工,2021,41(11):58-62.[3] 张艳华,宋光武,罗志云,等.烟气深度余热回收技术对燃气锅炉NOx排放扩散迁移规律的影响研究[J].环境科学学报,2016,36(3):1064-1069.[4] 徐顺生,于东港,鞠澄源,等.鼓风式燃气灶低氮燃烧数值模拟研究[J].过程工程学报,2023,23(3):438-450.[5] 肖鑫.基于空气加湿技术的燃气锅炉低氮燃烧特性研究[D].北京:北京建筑大学,2021.[6] 王小龙,张飞龙,王里,等.一次风速对高浓度煤粉预燃式低氮燃烧器性能影响的数值模拟[J].洁净煤技术,2021,27(4):132-138.[7] 姬海民,王电,石敬恒,等.基于FGR系统的新型低氮燃气燃烧器在燃气锅炉NOx排放中应用[J].热力发电,2018,47(2):103-107.[8] 薄建民,詹爽,张娣,等.乙烯裂解炉脱硝降氮技术及其应用[J].化工机械,2022,49(3):509-514.[9] 粟伟明.燃气锅炉烟气污染物排放现状分析研究及解决措施[C]//第十一届全国能源与热工学术年会论文集.马鞍山:中国金属学会能源与热工分会,2021:376-381.[10] 李磊,王晓鹏,马虹,等.基于生命周期评价的燃气工业锅炉低氮燃烧技术综合评价[J].环境污染与防治,2022,44(7):907-910.[11] 李源,毛睿,任利明,等.非均匀来流条件下SCR系统静态混合器布置及喷氨优化数值模拟研究[J].热能动力工程,2021,36(6):78-85.[12] 卢志民,李文庆,廖永进,等.基于影响因子的SCR脱硝系统喷氨量优化模拟[J].中国电机工程学报,2021,41(14):4923-4930.[13] 张鹏,贾媛媛,唐中华,等.钒钛系脱硝催化剂抗SO2和H2O中毒性能研究进展[J].现代化工,2021,41(4):67-71.[14] 谭增强,姚皓,周梦伟,等.SCR脱硝全区域NH3/NOx等摩尔比优化研究[J].河南理工大学学报(自然科学版),2022,41(2):85-92.[15] 葛铭,姚宣,刘柱,等.分区控制式喷氨格栅脱硝系统流场及喷氨均匀性研究[J].煤炭转化,2022,45(3):95-102.[16] 杨松.氨逃逸测量技术在脱硝系统中的应用研究与优化[J].现代化工,2018,38(6):216-219.[17] 徐继法,朱繁,邱明英,等.基于响应面分析的SCR催化剂单孔脱硝反应研究[C]//第十三届中国钢铁年会论文集—9.能源、环保与资源利用.重庆:中国金属学会,2022:247-252.